Add to Cart
High And Low Temperature Alternating Test Chamber B-T-225L Temp Range -70-150℃ SUS #304
1. Arc molding and fog surface line processing, high texture appearance, and the use of flat no reaction handle, easy to operate, safe and reliable;
2. Closed structure, strong circulating motor, low voice freezing device; With shockproof pad, so that the machine can keep quiet and stable during operation;
3. Has the power test function of the tested part (load test);
4. Lighting window lamp, built-in high temperature resistant defogging device, easy to observe the test of products in the box; With a variety of protective devices, safe and reliable performance.
5. Super thick insulation layer, observation window five layers of vacuum glass, cooling heat does not lose, to ensure the rapid and stable rise and fall.
6. Ventilation dry and wet table and the whole machine should be integrated as a whole, it can not be attached by the user at will, this is because the ventilation dry and wet table has strict wind speed requirements, the wind speed is different from the temperature and humidity test box, it can only be installed in special parts.
7. The surface escape method is used for humidification. Water molecules are added into the air in this method. The humidification surface is large, the release is stable, and the humidity fluctuation is small and the distribution is uniform. If the use of ultrasonic or steam humidification, add is small water droplets, that is, add water rather than real humidity, humidification surface is small, impact is large, humidity fluctuation and uneven distribution.
8. The suspended items under test do not need to be fixed. They do not swing. Once they swing, they will have trouble reading and colliding with each other.
9. The measured items will not block each other. If there is a block, the equipment can only meet the index in the empty box test, but the uniformity index is very poor in actual use.
10. The cooling parts of the equipment can not be condensed or frozen, the longer the time, the more icing, and finally all the blockage, air can not pass through, air circulation performance decline resulting in a decline in control quality.
box structure:
The box body is made of CNC machine tool processing, beautiful and generous, and the use of no reaction handle, easy to operate.
Box liner adopts imported advanced stainless steel (SUS304) mirror plate, box liner adopts A3 steel spray, increasing the appearance texture and cleanliness.
The water tank is placed in the lower right part of the control box, and has automatic water shortage protection, more convenient for the operator to replenish water.
Large observation window with lights to keep the box bright, and the use of heating body embedded toughened glass, clear observation of the box at any time.
The humidifier system pipes are separated from the control circuit board to avoid faults caused by water leakage in the humidifier pipes and improve safety.
Waterway system piping circuit system is easy to maintain and overhaul.
Superfine glass fiber insulation cotton is used to prevent unnecessary energy loss.
A test hole with a diameter of 50mm is provided on the left side of the box, which can be used to connect external test power cables or signal cables.
| model | B-RUL-45 | B-RUL--60 | B-RUL-80 | B-RUL-100 | ||||||
design dimension | 45x45x45 | 60x60x60 | 80x80x80 | 100x100x100 | |||||||
carton size | 103x123x77 | 118x138x92 | 138x158x112 | 158x178x132 | |||||||
RT+10℃-200℃(1300°℃) | |||||||||||
economy | model
| DHG-9030A 101A-0S | DHG-9070A 101A-1S | DHG-9140A 101A-2S | DHG-9240A 101A-3S | DHG-9420A 101A-4S | DHG-9620A | ||||
volume | 30L | 70L | 136L | 220L | 420L | 620L | |||||
Interior dimension | 350*350*350 | 450*350*450 | 550*450*550 | 600*500*750 | 640*585*1355 | 840*600*1355 | |||||
mmW*D*H carton size | 480*470*685 | 580*470*785 | 680*590*885 | 730*640*1085 | 780*750*1880 | 980*800*1880 | |||||
temperature fluctuation | ±1℃ | ±1℃ | ±1℃ | ±1℃ | ±1℃ | ±1℃ | |||||
temperature resolution | 0.1℃ | 0.1℃ | 0.1℃ | 0.1℃ | 0.1℃ | 0.1℃ | |||||
temperature control range | RT+10-250℃ | RT+10-250℃ | RT+10-250℃ | RT+10-250℃ | RT+10-200℃ | RT+10-200℃ | |||||
mains input | 220V 50HZ | 220V 50HZ | 220V 50HZ | 220V 50HZ | 220V 50HZ | 220V 50HZ | |||||
input powe | 650W | 1500W | 2000W | 2400W | 4000W | 4800W | |||||
volume | 30L | 70L | 136L | 220L | 420L | 620L |